ReferenceDataSetWriter
Short description
ReferenceDataSetWriter writes new changes to the selected reference data set in the Data Manager. The changes must be approved in the Data Manager before they can be read.
This component must run on CloverDX Server. It only connects to the Data Manager instance deployed in the same CloverDX Server instance where it is running. |
Data output | Input ports | Output ports | Transformation | Transf. req. | Java | CTL | Auto-propagated metadata |
---|---|---|---|---|---|---|---|
Any reference data set in Data Manager |
1 |
1 |
✓ |
⨯ |
⨯ |
✓ |
✓ |
Ports
Port type | Number | Required | Description | Metadata |
---|---|---|---|---|
Input |
0 |
✓ |
For the data to write to the data set. |
Auto-propagated based on the layout of the selected data set with two extra fields called |
Output |
0 |
⨯ |
For records successfully written to the data set. |
Auto-propagated based on the layout of the selected data set – contains all data set fields. |
Metadata
The ReferenceDataSetWriter component propagates metadata on the input port. The input metadata is created based on the layout of the selected data set. If different metadata is used, you can configure the Input mapping to map the incoming records to records required by the data set.
ReferenceDataSetWriter attributes
Attribute | Req | Description | Possible values |
---|---|---|---|
Basic |
|||
Data Set |
✓ |
Data set to write to. Clicking on the select button will show all reference data sets available on the Server. |
|
Input mapping |
Allows you to map incoming records to records in the data set. Default mapping (when nothing is configured) is to map by name. |
||
Output mapping |
Allows you to map data written to the data set to the output port. By default, this is set to Map by name and fields with matching names and types will be mapped automatically. This is consistent with the common usage where the metadata on output port 0 is auto-propagated and will match the data set exactly. |
Details
ReferenceDataSetWriter connects to an instance of Data Manager running on the same Server as the component and inserts new records into the selected reference data set, or updates existing records.
If you do not provide the _id
in the Input mapping (i.e, the _id
is null
) a new record will be created. This record will get new, auto-generated
_id
value that will be returned via the Output mapping.
If you provide an _id
value, then:
-
If the
_id
matches an existing record in the lookup, a new change record is written for the record with this_id
. If a change record already exists, it is completely overwritten (there can be only one change record for each_id
value). -
If the
_id
does not match an existing record, the graph fails.
Changes made by ReferenceDataSetWriter are not published automatically, but require an approval by the Data Approver user in the Data Manager. Only approved changes can be read by ReferenceDataSetReader component.