InformixBulkWriter

InformixDataWriter 64x64

Short description

Ports

Metadata

InformixBulkWriter attributes

Details

Compatibility

See also

Short description

InformixBulkWriter loads data into an Informix database.

When to use InformixBulkWriter

This component requires installation and configuration of a database native client. The client must be installed on the same machine as CloverDX Server (when working in a server project) or CloverDX Designer (when working in a local project). Due to this overhead, we recommend using this component only if you require significantly higher loading performance than with DatabaseWriter which should be used in typical scenarios.

Data output Input ports Output ports Transformation Transf. required Java CTL Auto-propagated metadata

database

0-1

0-1

Ports

Port type Number Required Description Metadata

Input

0

[1]

Records to be loaded into the database

Any

Output

0

For information about incorrect records.

1

 If no file containing data for loading (Loader input file) is specified, the input port must be connected.

2

 Metadata on the output port 0 contains two additional fields at their end: number of row, error message.

Metadata

InformixBulkWriter does not propagate metadata.

Metadata on the output port 0 contains two additional fields at their end: number of row, error message.

Field number Field name Data type Description
Table 55. Error fields for InformixBulkWriter

LastInputField + 1

<anyname1>

integer

The number of the row.

LastInputField + 2

<anyname2>

string

The error message.

InformixBulkWriter attributes

Attribute Req Description Possible values

Basic

The path to the dbload utility.

yes

The name of the dbload utility, including the path. The Informix server must be installed and configured on the same machine where CloverDX runs and the user must be logged in as root. The dbload command line tool must be available.

Host

The host where the database server is located.

Database

yes

The name of the database into which the records should be loaded.

Database table

yes

The name of the database table into which the records should be loaded.

Advanced

Control script

The control script to be used by the dbload utility. If it is not set, the default control script is used instead. Is used only if the Use load utility attribute is set to false.

Error log URL

The name of the error log file, including the path. If not set, the default error log file is used instead.

./error.log

Max error count

The maximum number of allowed records. When this number is exceeded, the graph fails.

10 (default) | 0-N

Ignore rows

The number of rows to be skipped. Used only if the Use load utility attribute is set to false.

0 (default) | 1-N

Commit interval

Commit interval in number of rows.

100 (default) | 1-N

Column delimiter

One character delimiter used for each column in data. Field values must not include this delimiter as their part. Used only if the Use load utility attribute is set to false.

"|" (default) | other character

Loader input file

The name of the input file to be loaded, including the path. Normally, this file is a temporary storage for data to be passed to the dbload utility unless named pipe is used instead.

Deprecated

Use load utility

By default, the dbload utility is used to load data to the database. If set to true, load2 utility is used instead of dbload. The load2 utility must be available.

false (default) | true

User name

The username to be used when connecting to the database. Used only if the Use load utility attribute is set to true.

Password

The password to be used when connecting to the database. The password is used only if the Use load utility attribute is set to true.

Ignore unique key violation

By default, unique key violation is not ignored. If key values are not unique, the graph fails. If set to true, unique key violation is ignored. The attribute is used only if the Use load utility attribute is set to true.

false (default) | true

Use insert cursor

By default, the insert cursor is used. Using the insert cursor doubles the transfer performance. Used only if the Use load utility attribute is set to true. Disable it by setting the value to false.

true (default) | false

Details

InformixBulkWriter loads data into a database using the Informix database client (dbload utility) or the load2 free library.

It is very important to have the server with the database on the same computer as both the dbload database utility and CloverDX; furthermore, you must be logged in as the root user. The Informix server must be installed and configured on the same machine where CloverDX runs and the user must be logged in as root. The Dbload command line tool must also be available.

InformixBulkWriter reads data from the input port or a file. If the input port is not connected to any other component, data must be contained in a file that should be specified in the component.

If you connect a component to the optional output port, rejected records along with information about errors are sent to it.

Another tool is the load2 free library instead of the dbload utility. The load2 free library can be used even if the server is located on a remote computer.

Loader input file

The name of the input file to be loaded, including the path. Normally, this file is a temporary storage for data to be passed to the dbload utility unless named pipe is used instead.

  • If it is not set, a loader file is created in CloverDX or the OS temporary directory. The file is deleted after the load finishes.

  • If it is set, a specified file is created. It is not deleted after data is loaded and it is overwritten on each graph run.

  • If the input port is not connected, this file must exist, must be specified and must contain data that should be loaded into database. It is not deleted or overwritten.

Compatibility

Version Compatibility Notice

4.7.0-M2

The attributes Use load utility, User name, Password, Ignore unique key violation and Use insert cursor were deprecated.

5.3.0